RUNNER LINK Gateway Configuring the Runner Link
11
3. On the Runner Link board, press the Config button for minimum of 3
seconds.
The red FAIL LED lights and then after 3 seconds the green NET LED lights
as well and the green SYSTEM LED starts to blink. There is an audible beep
from your PC (acknowledgment) and the FAIL and NET LEDS turn off. The
screen then is populated with the default IP addresses from the board.
4. Change the Authorized PC IP address to the normal working IP of your PC.
NOTE
This IP address MUST be used for maintaining the alarm system.
5. In the IP Runner link pane, select the radio button required for the network
the Runner Link is connected to.
If a static address is needed all the required information must be entered
manually.
6. In the Receiver pane, change the IP addresses of the Receiver servers to
those of the Monitor Service Provider.
7. Enter the correct account number given by the Service Provider so that the
unit can be found rapidly when the operator needs to contact it.
The Monitor Service Provider is able to contact the unit by using the Account
number, which is the actual address of the unit.
8. Click the
button.
The screen closes and only the green SYS LED continues to blink. The other
two LEDS are OFF.
9. Set the IP of your laptop back to your normal working IP.
10. Disconnect the cross cable from the Runner Link and connect the Runner Link
to the LAN or WAN.